Konik saptırıcılı ısıtıcı borunun etkinliğinin deneysel araştırılması

Experimental investigation of effectiveness of heating tube with conical baffles

Journal Name:

Publication Year:

DOI: 
10.5505/pajes.2016.69077

Keywords (Original Language):

Author NameUniversity of AuthorFaculty of Author
Abstract (2. Language): 
In this paper, effectiveness of heated tube with conical baffles was studied experimentally as a function of various inclination angles. By using inclined conical baffles vortex of the flow was increased thereby giving rise to heat transfer and the best inclination angle was determined. Experiments were performed for three different inclination angles (45°, 60° ve 80°). Water as hot fluid and air as cold fluid were used as working fluids in the experiments. Water temperature was fixed as 65 °C. Air flow velocities were taken at 8 distinct levels between 2-20 m/s. The results indicated that for NTU>1, 45° and 80° were more effective compared to 60°. In addition for NTU<1, all three angles were found to be similarly effective.
Abstract (Original Language): 
Bu çalışmada, konik saptırıcılı ısıtıcı borunun farklı eğim açıları için etkinlikleri deneysel olarak araştırılmıştır. Eğilmiş konik saptırıcılar vasıtasıyla daha büyük vorteks akışlar sağlanarak ısı transferi artışı sağlanmış ve etkinlik bakımından en iyi eğim açısı belirlenmiştir. Deneyler, üç farklı eğim açısı (45°, 60° ve 80°) için gerçekleştirilmiştir. Çalışmada, ısıtılan akışkan olarak hava, ısıtıcı akışkan olarak ise su kullanılmıştır. Isıtıcı su sıcaklığı, 65 °C'da sabit tutulmuştur. 2-20 m/s arasında sekiz farklı hava akış hızı için deneysel sonuçlar elde edilmiştir. NTU>1 için elde edilen sonuçlar, 45° ve 80°'nin etkinliğinin, 60°'ile karşılaştırıldığında daha büyük olduğu gösterilmiştir. Buna ek olarak, NTU<1 için ise üç açının etkinlik değerlerinin birbirine yakın olduğu bulunmuştur.
378
382

REFERENCES

References: 

[1]
Durmu
ş A, Kurtbaş İ, Gülçimen F, Durmuş A. "Akım ortamina yerleştirilen kesik konik türbülatörlerin sabit yüzey sicakliğina sahip bir tüpde isi transferi ve ekserji kaybina etkisi". Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi, 4(3), 175-184, 2002.
[2]
Koyu
n T, Avcı S. "Yeni tasarlanan bir isi değiştirgeci ile konvansiyonel isi değiştirgeçlerinin deneysel olarak karşilaştirilmalari". Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, 20(4), 116-122, 2014.
[3] Şahin HM, Baysal E, Dal AR. "Experimental and numerical investigation of thermal characteristics of a novel concentric type tube heat exchanger with turbulators". International Journal of Energy Research, 37(9), 1088-1102, 2013.
[4] Yakar G, Karabacak R. "Investigation of thermal performance of perforated finned heat exchangers". Experimental Heat Transfer, 28(4), 354-365, 2015.
[5] Promvonge P, Tamna S, Pimsarn M, Thianpong C. "Thermal characterization in a circular tube fitted with inclined horseshoe baffles". Applied Thermal Engineering, 75, 1147-1155, 2015.
[6] Anvari AR, Lotfi R, Rashidi AM, Sattari S. "Experimental research on heat transfer of water in tubes with conical ring inserts in transient regime". International Communications in Heat and Mass Transfer, 38(5), 668-671, 2011.
[7] Lee DH, Jung JM, Ha JH, Cho YI. "Improvement of heat transfer with perforated circular holes in finned tubes of air cooled heat exchanger". International Communications Heat Mass Transfer, 39(2), 161-166, 2012.
[8] Yaghoubi M, Mandavi M. "An investigation of natural convection heat transfer from a horizontal cooled finned tube". Experimental Heat Transfer, 26(4), 343-359, 2013.
[9] Moffat R J. "Describing the uncertainties in experimental results". Experimental Thermal and Fluid Science, 1(1),
3-17, 1988.
[10]
Çenge
l YA. Isı ve Kütle Transferi: Pratik Bir Yaklaşım. 3. Baskı. İzmir, Türkiye, Güven Kitabevi, 2011.