You are here

EMETROP ORTAOKUL ÖĞRENCİLERİNDE YOĞUN OKUMANIN MİYOPİ OLUŞUMUNA ETKİSİNİN PROSPEKTİF İNCELENMESİ: İLK SONUÇLAR

Effect of intensive reading on the development of myopia in emmetropic secondary school children: The preliminary results

Journal Name:

Publication Year:

Abstract (2. Language): 
Purpose: To reveal the effect of intensive reading on myopic development in secondary school children with emmetropic eyes. Methods: Both eyes of 77 male children (n = 97) with mean age of 12.70 years and mean 6 hours of reading (Group 1) were compared prospectively with the eyes of 36 children (n = 72) with mean age of 13.31 years without reading (Group 2) by means of cycloplegic refraction and ultrasonic biometric measurements at intervals of 18 months. Results: Myopic shift was present in 68 (72.3%) of 97 eyes by means ofcyclopleg ic refraction in Group 1. The mean anterior chamber depth (ACD), axial length (ALX), and keratometric (K) readings were sign if cantly higher after 18 months than first measurements (p = .0001 for all) in Group 1. There were no any statistically significant differences between two measurements of these parameters in Group 2 except increasing in keratometric readings. Conclusion: Our preliminary results show that reading and writing, one of the important environmental factor, causes refract ve myop c sh ft n emmetrop c male schoolch ldren, and is related with statistically signifcant increase in both ALX and K readings.
Abstract (Original Language): 
Amaç: Emetrop gözlerde yoğun okumanın miyopi gelişimi üzerindeki etkisinin 7 yıl süreli prospektif araştırılması. Metod: Yaş ortalamaları 12.70 olan, günde ortalama 6 saat okuma-yakın çalışma yapan 77 erkek ortaokul öğrencisinin 97 gözü ile (l.Grup), yaş ortalamaları 13.31 olan, okumayan ve sanayi mesleklerinde çalışan 36 çırağın 72 gözü (2.Grup=kontrol)18 ay arayla sikloplejik refraksiyon (SKP-R) ve ultrason i k biyometri k ölçümler yapılarak karşılaştırıldı. Bulgular: Birinci grupta sikloplejik refraksiyona göre 97 gözün 68 (%72.3)'inde miyopiye kayma oldu. Yine l.Grupta 18 ayarayla alınan SKP-R, keratometre (K), ön kamara derinliği (ÖKD) ve aksiyel uzunluk (AU) ölçümlerinde anlamlı artış vardı (her üç değer için p=0.0001). İkinci grupta se, K değerler ndek artış dışında hem refraks yondak hem de biyometrik parametrelerdeki fark anlamsızdı. Sonuç: Çalışmamızın ön sonuçları, öneml b r çevresel faktör olan okuma-yazmanın emetrop öğrencilerde miyopi yönünde refraksiyon değişimi yaptığını ve bu değişimin hem ÖKD ve AU hem de K değerindeki artma ile birlikte olduğunu göstermştr.
148-152

REFERENCES

References: 

1. Ph ill i ps C. Aet iologyofmyop ia. Br J Ophthalmol 1990; 77:77-8.
2. Angle J, Wissman DA. The ep i dem iology of myop i a. Am J Ophthalmol 1980; 111:220-8.
3. Ri chler A, Bear JC. Refract ion, near-work and educati on; apopulat ion study in Newfoundland. Acta Ophthalmol 1980; 88:768-78.
7. Young FA. The nature and control of myop ia. J Am Optom Assoc 1977;
78:781-7.
8. Parssinen O, Hemm i nki E, Klemetti A. Effect of spectacle use and accommodati on on myop i c progression; final results of a three-year random i sed cl in i cal trial among schoolch i ldren. Br J Ophthalmol 1989;
73:877-81.
6. Parssinen O, Lyyra AL. Myopia and myopic progression among schoolch i ldren: a three year follow-up study. Invest Ophthalmol Vi s Sc i 1993; 37:2797-802.
7. Tschern i ng M. Graefes eyes, and l iv ing hab its among men aged 33-37 years. Acta Ophthalmol 1988; 63:398-700.
8. Parssinen O. The wear ing of spectacles and occurance of myop i a. Acta Ophthalmol 1986; 207:SerA.
9. Taylor HR. Rac ial variat ions i n vi sion. Am J Ep idem i ol 1981; 113:62-80.
10. Obsfeld H. Crystalli ne lens accommodati on and anteri or chamber depth. Ophthal Physiol Opt 1989; 9:36-70.
11. Storey JK, Rabie EP: Ultrasound. A research tool i n the study of accommodati on. Ophthalm i c Physiol Opt 1983; 3:318-20.
12. Lepper RD, Trier HG: Measurement of accommodat ive chances i n human eyes by means of a h igh resolut ion ultrason i c system. In Osso in i ng KC, ed. Doc Ophthalmol Proc Seri es 78: Ophthalm i c Echography, Proceed i ngs of the 10th SIDUO Congress. Dordrecht, Marti nus, N ijhoff/Dr.WJunk. Publ i shers 1987: 187-62.
13. Coleman DJ, Wuch i n ich E, Carl in B. Acommodat ive changes i n the ax ial d imenti ons of the eye. In: Gitter KA, ed. Ophthalm i c Ultrasound. St. Lu i s: Mosby 1969: 137-71.
17. Sori ano HM: Echograph i c find i ngs in accommodati on. In Ossoi n ing KC, ed. Doc Ophthalmol Proc Seri es 78: Ophthalm i c Echography, Proceed i ngs of the 10th SIDUO Congress. Dordrecht, Mart i nus, N ijhoff/Dr.WJunk. Publ i shers 1987: 16370.
18. Shum PJT, Ko LS, NgCL, L in SL. A b iometri c study of ocular changes during accommodat ion. Am J Ophthalmol 1993; 118:76-81.
16. Goss DA. Clinical accommodation and heterophoria findings preceding juvenile onset of myopia. Optom Vis Sci 1991; 68:110-6.
17. Coleman DJ. Unified model of accommodative mechanism. Am J Ophthalmol 1970; 69:1063-79.
18. Fontana ST, Brubaker RF. Volume and depth of the anterior chamber of the normal aging human eye. Arch Ophthalmol 1980; 98:1803-8.
19. McBrien NA, Millodot M. A biometric investigation of late onset myopic eyes. Acta Ophthalmol 1987; 68:761-8.
20. Adams AJ. Axial length elongation, not corneal curvature, as a basis of adult onset myopia. Am J Optom Physiol Opt 1987; 67:180-2.
21. Raviola E, Wiesel TN. An animal model of myopia. NEnglJ Med 1988;
312:1609-18.
22. Hosaka A. The growth of the eye and its components. Acta Ophthalmol
1988; 188:68-7.
23. McBrien NA, Adams DW. A longitudinal investigation of adult-onset and adult-progression of myopia in an occupational group: refractive and biometric findings. Invest Ophthalmol Vis Sci 1997; 38:321-33.
27. Bullimore MA, Gilmartin B, Royston JM. Steady-steate accommodation and ocular biometry in late onset myopia. Doc Ophthalmol 1992; 80:173-88.
28. Jiang BC, Woessner WM. Vitreus chamber elongation is responsible for myopic development in a young adult. Optom Vis Sci 1996; 73:231-7.
26. Mei Q, Rong Z. Early signs of myopia in Chinese schoolchildren. Optom Vis
Sc 1997; 71:17-6.