You are here

Antifriz Su Karışımının Eş Merkezli-Borulu Isı Değiştiricideki Isı Transfer Performansının Deneysel İncelenmesi

The Experimental Investigation of Heat Transfer Performance of Antifrezee-Water Mixture In Concentric Tube Heat Exchanger

Journal Name:

Publication Year:

Author NameUniversity of AuthorFaculty of Author
Abstract (2. Language): 
In this paper, some experiments, releated to heat convection occuring during the heat transfer from antifreeze (Ethylene-Glycol mix., %50 - %50, respectively)-water mixture (%75 - %25, %50 - %50, %25 - %75, respectively) (hot fluid) to water (cold fluid) in concentric tube heat exchangers, have been performed and the general performance of the system has been investigated. Using the data which was obtained from the experiments, logarithmic mean temperature difference (LOSF), the coefficient of total heat transfer with conduction (U), the coefficients of the inside and outside surface heat transfer with convection (hask - hso) and heat transfer rates (Q) in the counter and parallel flow have been compared in graphics. From the exeperimental data, it was found out that opposite flow transfers average 300 W heat more than paralel flow in the concentric tube heat exchanger.
Abstract (Original Language): 
Bu çalışmada aynı merkezli-borulu ısı değiştiricilerde farklı karışım oranlarındaki (%75-%25, %50-%50, %25-%50) antifiriz (Ethylene-Glycol karışımı, %50 - %50) su karışımından (sıcak akışkan) suya (soğuk su) ısı geçişi esnasında meydana gelen ısı transfer özelliklerinin belirlenmesi ile ilgili deneyler yapılmış ve sistem genel performansı araştırılmıştır. Deneylerden elde edilen verilerle logaritmik ortalama sıcaklık farkı (LOSF), toplam ısı transfer katsayısı (U), iç ve dış yüzey ısı taşınım katsayıları (hsı - hso) ile karşıt ve paralel akışlardaki ısı transfer oranları (Q) grafikler yardımıyla karşılaştırılmıştır. Deneysel sonuçların incelenmesinden aynı merkezli-borulu ısı değiştiricide, sıcak akışkanın karşıt akışta paralel akışa göre yaklaşık 300 W'lık daha fazla ısı transferi olduğu görülmüştür.
1-13

REFERENCES

References: 

[1]
Çengel
, Y. A., Boles, M. A., Derbentli, T., "Mühendislik Yaklaşımıyla
Termodinamik", Mc Graw-Hill- Literatür Yayınları, 1996, p. 1-867. [2] www. engineeringtoolbox. com [3] www.jcna.com
11
[4] Igarashi, T., Nakamura, H., Fukuoka, T., "Pressure Drop and Heat Transfer of Arrays of In-Line Circular Blocks on The Wall of Parallel Channel", International Journal of Heat and Mass Transfrer, 2004, 47, p. 4547-4557.
[5] Sanidjai, S., Goldstein, R. J., "Forced Convection Heat Transfer from a Circular Cylinder in Crossflow to Air and Liquids", International Journal of Heat and Mass
Transfrer, 2004, 47, p. 4795-4805.
[6] Shanmugama, V., Natarajanb, E., "Experimental investigation of forced convection and desiccant integrated solar dryer", Renewable Energy, 2006, 31, p. 1239-1251.
[7] Hashemabadi, S. H., Etemad, S. G., Tihibault, J., "Forced Convection Heat Transfer of Couette-Poiseuille Flow of Nonlinear Viscoelastic Fluids Between Parallel Plates", International Journal of Heat and Mass Transfrer, 2004, 47, p. 3985-3991.
[8] Saeid, N. H., "Analysis of Mixed Convection in a Vertical Porous Layer Using Non-Equilibrium Model", International Journal of Heat and Mass Transfrer, 2004, 47, p. 5619-5627.
[9] David, K., Huang, A., Sheng-Chung, T., Wei-Ping, M., "Effects of anti-freeze concentration in the engine coolant on the cavitation temperature of a water pump",
Applied Energy, 2004, 79, p. 261-273.
[10] Wang, S., S., Lin, Y., "A new technique for detecting antifreeze in engine oil during early stage of leakage", Sensor and Actuatörs B, 2003, 96, p. 157 - 164.
[11] Lottin, O., Epiard, C., " Dependence of the thermodynamic properties of ice slurries on the characteristics marketed antifreezes", International journal of
refrigeration, 2001, 24, p. 455-467.
[12] Comyn, J., Day, J., Shaw, S., J., "Durability of aluminium-sealant joints in jet-fuel, water and antifreeze", Int. J. Adhesıon And Adhesıves, 1997, 17, p. 213 - 221.
[13] Ayel, V., Lottin, O., Popa, E., Peerhossaini, H., "Using undercooling to measure the freezing points of aqueous solutions", International journal of thermal sciences, 2005, 44, p. 11 - 20.
[14] Ayel, V., Lottin, O., Faucheux, M., Sallier, D., Peerhossaini, H., "Crystallisation of undercooled aqueous solutions: Experimental study of free dendritic growth in cylindrical geometry", International journal of heat and mass transfer, 2006, 49, p. 1876 - 1884.
12
[15] Imura, H., Koito, Y., Mochizuki, M., Fujimura, H., "Start-up from the frozen state of two-phase thermosyphons", Applied Thermal Engineering, 2005, 25, p. 2730 -
2739.
[16] İnanlı, M., Esen, H., "Experimental thermal performance evaluation of a horizontal ground-source heat pump system", Applied Thermal Engineering, 2004, 24, p. 2219
- 2232.
[17] Lottin, O., Ayel, V., Peerhossaini, H., "Ice slurries phase transition thermodynamics: relations for determining concentration-temperature domains of application", International Journal of Refrigeration, 2004, 27, p. 520 - 528.
[18] Rommel, M., Mock, W., "Collector efficiency factor f for absorbers with rectangular fluid ducts contacting the entire surface", Solar Energy, 1997, 60, p. 199
- 207.
[19] Huang, K., D., Tzeng, S., C., Ma, W., P., "Effects of anti-freeze concentration in the engine coolant on the cavitation temperature of a water pump", Applied Energy,
2004, 79, 261 - 273.

Thank you for copying data from http://www.arastirmax.com