Buradasınız

DEĞİŞİK SICAKLIKLARDA İŞLETİLEN BİR BİYODİSK ÜNİTESİNİN PERFORMANSININ BELİRLENMESİ

PERFORMANCE OF ROTATING BIOLOGICAL CONTACTORS OPERATING AT DIFFERENT TEMPERATURES

Journal Name:

Publication Year:

Author NameUniversity of AuthorFaculty of Author
Abstract (2. Language): 
An investigation was carried out to define the effects of temperature change on the biological wastewater treatment using a Rotating Biological Contactors (RBC). The major investigation was to establish the optimum operational conditions of the unit and to determine how its efficiency was affected by temperature. During the investigation, the substrate employed was a synthetic wastewater made up frequently in the laboratory. Experimental works were conducted at three constant temperature, 10 °C, 20 °C and 30 °C. There was a considerable increase in efficiency of the unit, measured by removal of organic material, between 10 °C and 20 °C, but much less of a change from 20 °C to 30 °C. These variations were reflected by the rate of formation of total oxidized nitrogen in the unit.
Abstract (Original Language): 
Bu çalışma, bir biyodisk ünitesi kullanarak sıcaklık değişimlerinin biyolojik atıksu arıtımı üzerine etkisinin belirlenmesi için gerçekleştirilmiştir. Çalışmanın büyük çoğunluğunda biyodisk ünitesi için optimum işletim şartları belirlenmeye çalışılmış ve bu esnada ünite performansının sıcaklık değişimleri tarafından nasıl etkileneceği araştırılmıştır. Çalışmada atıksu kaynağı olarak laboratuar şartlarında hazırlanmış sentetik atıksu kullanılmıştır. Deneysel çalışmalar üç değişik sıcaklıkta, 10 °C, 20 °C ve 30 °C'ta sürdürülmüştür. Sıcaklığın 10 °C ile 20 °C arasında değişmesi halinde organik madde gideriminde önemli miktarlarda artışlar olmasına rağmen sıcaklığın 20 °C ile 30 °C arasında değişmesi halinde çok fazla olmamıştır. Bu değişimler ünite içerisindeki toplam okside olmuş nitrojen oluşumunun ölçülmesi ile belirlenmiştir.
405
410

REFERENCES

References: 

Antonie, R. L. 1976. Fixed Biological Surfaces Wastewater Treatment, Chemical Rubber Company (CRC) Press, Inc., Cleveland, Ohio.
Boon, A. G. and Burgess, D. R. 1972. Effects of Diurnal Variations in Flow of Settled Sewage on the Performance of High Rate Activated Sludge Plants,
Water Pollut. Control, 71 (5), 493. P.
Borchardt, J. A. 1966. Nitrification in the Activated Sludge Process, Div. of San. and Water Resources Eng., University of Michigan, Ann Arbor.
Ellis, K. V. and Banaga, S. E. I. 1976. A Study of Rotating-disc Treatment Units Operating at Different Temperatures, Water Pollut. Control, 10 (1), 73.
Mühendislik Bilimleri Dergisi 1997 3 (3)
409
Journal of Engineering Sciences 1997 3 (3)
Performance of Rotating Biological Contactors Operating at Different Temperatures, A. Berktay
Hitdlebaugh, J. A. and Miller, R. D. 1981. Operational Problems with Rotating Biological Contactors, J. Water Pollut. Control Fed.,
53 (8), 1283.
Jenkins, S. H. 1969. Nitrification, Water Pollut. Control, 68 (6), 610.
Metcalf and Eddy, 1991. Wastewater Engineering; Treatment, Disposal and Reuse, 3rd Edition, McGraw-Hill Book.
Pike, E. B. 1978. The Design of Percolating Filters and Rotary Biological Contactors, Including Details of International Practice, Water Research Centre, Technical Report, TR93, Medmenham.
Pike, E. B. Smith, C. H. C. Evans, R. H. and
Harrington, D. W. 1982. Performance of Rotating Biological Contactors under Field Conditions, Water Pollut. Control, 81 (1), 10.
Poon, C. P. C., Chin, H. K. Smith, E. D. and
Mikucki, W. J. 1981. Upgrading with Rotating Biological Contactors for BOD Removal, J. Water
P o llut. Control Fed., 53 (4), 474.
Strom, P. F. and Chung, J. C. 1985. The Rotating Biological Contactor for wastewater Treatment, Advances in Biotechnological Processes, 5, 193.
Torpey, W. Heukelekian, N. H. Kaplovsky, A. J. and Epstein, R. 1971. "Rotating Disks with Biological Growths Prepare Wastewater for Disposal or Reuse", J. Water Pollut. Control Fed., 43 (11), 2181.
Weng, C. N. and Molof, A. H. 1974. Nitrification in
the Biological Fixed-film Rotating Disk System, J.
Water Pollut. Control Fed., 46 (7), 1674.
Wu, Y. C. and Smith, E. D. 1983. Temperature Effect on RBC Scale-up, Pollution Technology
Review, 104, 287.
Zanoni, A. E. 1967. Wastewater Deoxygenation at Different Temperatures, Water Research, 1 (7),
543.

Thank you for copying data from http://www.arastirmax.com